We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
ARAB HEALTH - INFORMA

Download Mobile App





Moderna Announces Positive Interim Phase 1 Data for mRNA-1273 Coronavirus Vaccine

By HospiMedica International staff writers
Posted on 19 May 2020
Print article
Illustration
Illustration
Moderna, Inc. (Cambridge, MA, USA) has announced positive interim clinical data from its Phase 1 study of mRNA-1273, its vaccine candidate against novel coronavirus (SARS-CoV-2).

The Phase 1 study is led by the National Institute of Allergy and Infectious Diseases (NIAID), part of the National Institutes of Health (NIH). Immunogenicity data are currently available for the 25 µg and 100 µg dose level (ages 18-55) after two doses (day 43) and at the 250 µg level (ages 18-55) after one dose (day 29). Dose dependent increases in immunogenicity were seen across the three dose levels, and between prime and boost within the 25 µg and 100 µg dose levels. All participants ages 18-55 (n=15 per cohort) across all three dose levels seroconverted by day 15 after a single dose. At day 43, two weeks following the second dose, at the 25 µg dose level (n=15), levels of binding antibodies were at the levels seen in convalescent sera (blood samples from people who have recovered from COVID-19) tested in the same assay. At day 43, at the 100 µg dose level (n=10), levels of binding antibodies significantly exceeded the levels seen in convalescent sera. Samples are not yet available for remaining participants.

At this time, neutralizing antibody data are available only for the first four participants in each of the 25 µg and 100 µg dose level cohorts. Consistent with the binding antibody data, mRNA-1273 vaccination elicited neutralizing antibodies in all eight of these participants, as measured by plaque reduction neutralization (PRNT) assays against live SARS-CoV-2. The levels of neutralizing antibodies at day 43 were at or above levels generally seen in convalescent sera.

mRNA-1273 was generally safe and well tolerated, with a safety profile consistent with that seen in prior Moderna infectious disease vaccine clinical studies. The sole incidence of a grade 3 adverse event in the 25 µg and 100 µg dose cohorts was a single participant at 100 µg who experienced grade 3 erythema (redness) around the injection site. To date, the most notable adverse events were seen at the 250 µg dose level, comprising three participants with grade 3 systemic symptoms, only following the second dose. All adverse events have been transient and self-resolving. No grade 4 adverse events or serious adverse events have been reported.

Moderna also announced the preclinical results from a viral challenge study in mice conducted in collaboration with NIAID and its academic partners. In this study, vaccination with mRNA-1273 prevented viral replication in the lungs of animals challenged with SARS-CoV-2. Neutralizing titers in Phase 1 clinical trial participants at the 25 µg and 100 µg dose levels were consistent with neutralizing titers that were protective in the mouse challenge model. Based on the interim Phase 1 data, the Moderna-led Phase 2 study will be amended to study two dose levels, 50 µg and 100 µg, with the aim of selecting a dose for pivotal studies. The NIAID-led Phase 1 study is being amended to include a 50 µg dose level cohort across each of the three age groups. Moderna anticipates the dose for the Phase 3 study to be between 25 µg and 100 µg and expects Phase 3 trial initiation in July, subject to finalization of the clinical trial protocol.

“These interim Phase 1 data, while early, demonstrate that vaccination with mRNA-1273 elicits an immune response of the magnitude caused by natural infection starting with a dose as low as 25 µg,” said Tal Zaks, M.D., Ph.D., Chief Medical Officer at Moderna. “When combined with the success in preventing viral replication in the lungs of a pre-clinical challenge model at a dose that elicited similar levels of neutralizing antibodies, these data substantiate our belief that mRNA-1273 has the potential to prevent COVID-19 disease and advance our ability to select a dose for pivotal trials.”

“With today’s positive interim Phase 1 data and the positive data in the mouse challenge model, the Moderna team continues to focus on moving as fast as safely possible to start our pivotal Phase 3 study in July and, if successful, file a BLA,” said Stéphane Bancel, Chief Executive Officer at Moderna. “We are investing to scale up manufacturing so we can maximize the number of doses we can produce to help protect as many people as we can from SARS-CoV-2.”

Related Links:
Moderna, Inc.

Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
12-Channel ECG
CM1200B
New
LED Surgical Light
Convelar 1670 LED+/1675 LED+/1677 LED+
New
Mobile Barrier
Tilted Mobile Leaded Barrier

Print article

Channels

Critical Care

view channel
Image: The BrioVAD System featuring the innovative BrioVAD Pump (Photo courtesy of BrioHealth Solutions)

Innovative Ventricular Assist Device Provides Long-Term Support for Advanced Heart Failure Patients

Advanced heart failure represents the final stages of heart failure, where the heart’s ability to pump blood effectively is severely compromised. This condition often results from underlying health issues... Read more

Surgical Techniques

view channel
Image: The new treatment combination for subdural hematoma reduces the risk of recurrence (Photo courtesy of Neurosurgery 85(6):801-807, December 2019)

Novel Combination of Surgery and Embolization for Subdural Hematoma Reduces Risk of Recurrence

Subdural hematomas, which occur when bleeding happens between the brain and its protective membrane due to trauma, are common in older adults. By 2030, chronic subdural hematomas are expected to become... Read more

Patient Care

view channel
Image: The portable biosensor platform uses printed electrochemical sensors for the rapid, selective detection of Staphylococcus aureus (Photo courtesy of AIMPLAS)

Portable Biosensor Platform to Reduce Hospital-Acquired Infections

Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The acoustic pipette uses sound waves to test for biomarkers in blood (Photo courtesy of Patrick Campbell/CU Boulder)

Handheld, Sound-Based Diagnostic System Delivers Bedside Blood Test Results in An Hour

Patients who go to a doctor for a blood test often have to contend with a needle and syringe, followed by a long wait—sometimes hours or even days—for lab results. Scientists have been working hard to... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.