New System with Insertable Biosensor to Revolutionize Continuous Glucose Monitoring

By HospiMedica International staff writers
Posted on 16 Aug 2024
Print article
Image: The insertable glucose sensor uses a compact and cost-effective phosphorescence lifetime imager and machine learning (Photo courtesy of American Chemical Society)
Image: The insertable glucose sensor uses a compact and cost-effective phosphorescence lifetime imager and machine learning (Photo courtesy of American Chemical Society)

Diabetes, which affects over 450 million people worldwide, requires continuous and accurate glucose monitoring to prevent serious health issues. Traditional methods, like frequent finger pricking, are uncomfortable and often lead to poor adherence to monitoring regimens. While current continuous glucose monitoring (CGM) systems alleviate some of these issues, they still face challenges such as high costs, limited sensor lifespan, and potential tissue irritation due to the invasiveness of electrode insertion. Now, a new CGM system has been developed to overcome these limitations by combining an insertable glucose biosensor with a phosphorescence lifetime imager (PLI) and sophisticated machine learning algorithms, providing a more reliable and economical option for real-time glucose monitoring.

A collaborative research effort involving the University of California, Los Angeles (UCLA, Los Angeles, CA, USA) has led to the development of a new CGM system that uses a biocompatible phosphorescence-based biosensor implanted subcutaneously. Unlike traditional CGMs that depend on electrochemical reactions, this new system measures glucose levels by detecting changes in the phosphorescence signals emitted from the biosensor. These signals, which have a significantly longer lifetime than tissue autofluorescence, are captured non-invasively through the skin by the compact PLI. A major advancement of this system is its ability to maintain accuracy despite sensor misalignment, a common issue with wearable devices. The PLI's neural network model analyzes phosphorescence lifetime images not only to determine glucose levels but also to identify misalignments, alerting users to adjust the device if necessary. This ensures accurate and reliable glucose readings even during physical activities or movements that could displace the sensor.

In the research published in ACS Nano, in vitro testing showed the PLI accurately classified glucose levels in normal, low, and high ranges with 88.8% accuracy and detected misalignments with 100% accuracy. This demonstrates that the system could greatly enhance glucose monitoring quality, potentially reducing the frequency of recalibrations and offering a smoother user experience. Cost-effectiveness is another key feature of the new CGM system. The smaller, more durable biosensor has a stable phosphorescence response for up to 12 weeks and maintains enzyme activity for over four weeks, significantly extending its lifespan and reducing the need for frequent replacements, a major cost factor in existing CGM systems. Additionally, the PLI’s compact and affordable design enhances its appeal for widespread use.

The broader potential applications for the PLI system include multiplexed sensing, allowing for simultaneous monitoring of multiple biomarkers. This could vastly expand the capabilities of wearable diagnostics, positioning the system as a versatile tool for real-time health monitoring across various conditions. This breakthrough in CGM technology represents a major advancement in diabetes management, combining advanced technology with patient-focused design to improve comfort, reduce costs, and ultimately enhance the quality of life for millions globally.

Related Links:
UCLA

Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Flocked Fiber Swabs
Puritan® patented HydraFlock®
New
Negative Pressure Wound Therapy Unit
VT•ONE
New
Central Monitoring System
Envoy Plus

Print article

Channels

Surgical Techniques

view channel
Image: Turn-by-turn guidance from Caresyntax provides real-time intraoperative support for the clinical team (Photo courtesy of Caresyntax)

AI-Powered Precision Surgery Platform to Make Procedures Smarter and Safer

The lack of seamless integration in medical technologies often results in inefficiencies, including unnecessary delays in surgery, increased potential for errors, and higher costs as equipment quickly... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
The Atellica VTLi Patient-side Immunoassay Analyzer, a high-sensitivity troponin I test at the bedside, delivers accurate results in just 8 minutes (Photo courtesy of Siemens Healthineers)

New 8-Minute Blood Test to Diagnose or Rule Out Heart Attack Shortens ED Stay

Emergency department overcrowding is a significant global issue that leads to increased mortality and morbidity, with chest pain being one of the most common reasons for hospital admissions.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.