We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
ARAB HEALTH - INFORMA

Download Mobile App




Vascular Access System Creates Durable AVF for Hemodialysis

By HospiMedica International staff writers
Posted on 30 Jul 2020
Print article
Image: The Ellipsys Vascular Access System (Photo courtesy of Avenu Medical)
Image: The Ellipsys Vascular Access System (Photo courtesy of Avenu Medical)
A novel device uses a small needle puncture and a catheter to create a percutaneous arteriovenous fistula (pAVF) for end-stage renal disease (ESRD) patients who require hemodialysis.

The Avenu Medical (San Juan Capistrano, CA, USA) Ellipsys is an image-guided vascular access system designed to access the proximal radial artery in the forearm with an outer access cannula, guidewire, and vessel capture construct under high frequency ultrasound guidance. Once in position, a select amount of low power thermal energy is used to cut the walls of the blood vessels and fuse the tissue, creating an in-vivo anastomosis without leaving any foreign material, including sutures, in the resulting AVF.

A new study conducted at Institut Mutualiste Montsouris (Paris, France) of 232 patients who had an Ellipsys pAVF created between May 2017 and July 2019 showed no adverse events, and 96% had fully functioning AVFs after one year, compared to surgically created fistulas, which have a patency rate of about 60%. In addition, the study reported that patients were able to begin using their pAVF for dialysis an average of four weeks after creation, with six percent of fistulas maturing in as little as two weeks. The study was published in the April 2020 issue of the Journal of Vascular Surgery.

“Vascular access is quite literally the lifeline for dialysis patients. The advantages of the percutaneous Ellipsys fistula are that it is a very safe, simple and reproducible way to create a fistula that will function for a long time with minimal interventions,” said lead author vascular surgeon Aexandros Mallios, MD. “One of the most important aspects of the study is that it offers a protocol for fistula creation, maturation and maintenance, which should make it easier for other physicians to adopt the relatively new procedure.”

“Dr. Mallios' results are very exciting, particularly with such a large patient population, as it adds to the growing body of evidence that this approach offers a safe and effective way to quickly create a functional percutaneous fistula,” said Mark Ritchart, President and CEO of Avenu Medical. “He also uses his valuable experience as a guide to enable more widespread use of percutaneous fistulas, which may improve patient safety by reducing reliance on riskier vascular access options.”

An AVF is the most recommended access for ESRD patients undergoing dialysis, created by connecting a patient's vein and artery to form a long-lasting site through which blood can be removed and returned. Alternatively, in patients who are unsuitable for a fistula, an AVG--a plastic conduit between an artery and a vein--may be used.

Related Links:
Avenu Medical
Institut Mutualiste Montsouris


Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
New
X-ray Diagnostic System
FDX Visionary-A
New
Digital Baby Scale
seca 354

Print article

Channels

Critical Care

view channel
Image: Researchers have designed a magnetoplasmonic strain sensor for wearable devices (Photo courtesy of Chemical Engineering Journal, DOI: https://doi.org/10.1016/j.cej.2024.155297)

Power-Free Color-Changing Strain Sensor Enables Applications in Health Monitoring

Wearable devices and smart sensors are revolutionizing health and activity monitoring, enabling functions like heart rate tracking and body movement detection. However, conventional tools like stethoscopes... Read more

Patient Care

view channel
Image: The portable biosensor platform uses printed electrochemical sensors for the rapid, selective detection of Staphylococcus aureus (Photo courtesy of AIMPLAS)

Portable Biosensor Platform to Reduce Hospital-Acquired Infections

Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The acoustic pipette uses sound waves to test for biomarkers in blood (Photo courtesy of Patrick Campbell/CU Boulder)

Handheld, Sound-Based Diagnostic System Delivers Bedside Blood Test Results in An Hour

Patients who go to a doctor for a blood test often have to contend with a needle and syringe, followed by a long wait—sometimes hours or even days—for lab results. Scientists have been working hard to... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.