ECG System | Hospimedica Expo
Summary
|
Products
Spacelabs Healthcare
ECG System  
Model: Cardioline touchECG
Quick Inquiry
Description
The Cardioline touchECG is a high-performance diagnostic ECG system based on the HD+ wireless digital acquisition module. It displays, acquires, prints and stores traces and provides interpretation. It integrates easily into data management and electronic patient record systems.
touchECG can be standalone or combined into multi-function workstations. It can include all necessary hardware and software, or (subject to survey) may be provided to work on locally-supplied computing hardware and system software. touchECG on a Windows tablet is an attractive alternative to a complete mobile trolley, for long walks or outreach.

Request Information
Request Price/Quote

Features
UI, main display formats, interpretation:
• Versatile and intuitive user interface. Display formats -
• Cabrera 3, 3+1, 3+3, 6 or 12 channels in automatic mode.
• 3, 6 or 12 channels rhythm strip.
• It can be supplied with Glasgow interpretation.


ECG Processing
• Frequency range 30 - 300bpm
• Sampling rate up to 1000Hz.
• Linear phase digital diagnostic high-pass filter (60601-2-25), 50/60Hz AC interference adaptive digital filter.
• Automatic 12-channel, Manual 3/6 channel, Review 12-channel.
• Standard or Cabrera leads.


ECG measurements
• All leads, medians, corrected.
• HR, Average RR.
• PR interval, QRS duration
• QT and QTc intervals (Hodges, Bazett or Fridericia formula).
• Max R (V5); (V6) and S (V1).
• Sokolow-Lyon index.
• P, R, T-axis


ECG Management
• Launch from BDT/GDT.
• Automatic collection of report to ECG Management


Print Management
• Resolution according to printer.
• Sensitivity/gain 5, 10, 20mm/mV.
• Auto - 25/50mm/s; 3, 3+1, 6, 12 channel standard or Cabrera, formats 12x1, 6x2, 3x4+1, 3x4+3.
• Manual - 5, 10, 25, 50mm/s; 3, 6, 12 channel standard or Cabrera, 12x1, 6+6, 3x1.
• Calibration and lead marker.


• ECG leads and cables: 12-lead (I, II, III, aVR, aVL, aVF, V1- V6), replaceable patient leads
• CMRR & dc input impedance: 115dB, 100Mohm
• A/D converter: 24-bit, < 1uV/LSB, 32,000 samples per second per channel
• Sample rate for signal analysis: 20-bit, 500 or 1000 samples per second, user selectable
• Dynamic range: +/- 400mV
• Bandwidth: Performance equivalent 0.05 – 300Hz
• Pacemaker detection: Hardware with digital convolution filter
• Defibrillator protection: AAMI/IEC Standard
• Front-end performance: ANSI/AAMI IEC 60601-2-25:2011
• Data transfer: Bluetooth 2.1+ EDR with Secure-Pairing
• Connectivity: Launch by BDT/GDT, Patient ID embedded and worklist automatic archiving in the connected database to Sentinel data management, SCP-PDF-XML-GDT, DICOM, HL7 option
• Computer: Mini tower or all-in-one PC, Windows tablet. Windows 8.1 or 10, Quad core 1.6GHz or higher, 2GB RAM, 8GB disc, Bluetooth 2.1+EDR. Keypad and mouse; LCD screen at least 12-15”, 640x480
• Regulatory: Class IIa, Rule 10 annex IX, TUV (1936) 510(K), product code DPS, Class II, 21 CFR 870.2340, Risk class B
• Trolley: Standard or configured to user requirement
• Printer: A4 laser, color or black & white or thermal
• Isolation transformer: Optional
• Workstation option: Subject to survey, may be deployed on customer-supplied workstation

Request Information
Request Price/Quote