We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Printed Artificial Neurons Stimulate Natural Brain Circuits

By HospiMedica International staff writers
Posted on 20 Apr 2026

Brain-machine interfaces depend on artificial signals that can engage living neural circuits, yet many devices produce simplified outputs that fail to trigger realistic activity. More...

These limitations slow progress toward neuroprosthetics for hearing, vision, and movement, and constrain efforts to build energy‑efficient neuromorphic systems. Engineers also need approaches that are manufacturable and biocompatible. To help address this challenge, researchers have now developed printed artificial neurons that directly communicate with living brain cells.

Northwestern University engineers created flexible, low‑cost artificial neurons that generate electrical signals realistic enough to activate biological tissue. The devices were validated on mouse brain slices, where they induced responses in real neurons. The work points to electronics that can communicate with the nervous system and could support future neuroprosthetic applications.

The devices use soft, printable materials designed to better mimic the structure and behavior of brain tissue. Electronic inks made from nanoscale flakes of molybdenum disulfide, a semiconductor, and graphene, an electrical conductor, are deposited onto flexible polymer substrates using aerosol jet printing. After printing, partial decomposition of the stabilizing polymer concentrates current into a narrow conductive filament, producing a sudden neuron-like response. The resulting artificial neurons can generate single spikes, continuous firing, and bursting patterns that closely resemble biological signaling.

For biological interfacing tests, investigators from Northwestern’s Weinberg College of Arts and Sciences applied the artificial neuron outputs to slices of mouse cerebellum. The artificial voltage spikes matched key biological features, including the timing and duration of living neuron spikes. These inputs reliably triggered activity in real neurons and activated circuits in a manner similar to natural signals.

The team reports that capturing diverse signaling patterns allows each artificial neuron to encode more information, which could reduce component counts and improve computing efficiency. The additive printing process places material only where needed, which simplifies manufacturing, lowers cost, and reduces waste. The findings were published on April 15 in Nature Nanotechnology and were supported by the National Science Foundation.

“The way you make AI smarter is by training it on more and more data. This data-intensive training leads to a massive power-consumption problem. Therefore, we have to come up with more efficient hardware to handle big data and AI. Because the brain is five orders of magnitude more energy efficient than a digital computer, it makes sense to look to the brain for inspiration for next-generation computing,” said Mark C. Hersam, Walter P. Murphy Professor of Materials Science and Engineering at Northwestern’s McCormick School of Engineering.

"Other labs have tried to make artificial neurons with organic materials, and they spiked too slowly. Or they used metal oxides, which are too fast. We are within a temporal range that was not previously demonstrated for artificial neurons. You can see the living neurons respond to our artificial neuron. So, we’ve demonstrated signals that are not only the right timescale but also the right spike shape to interact directly with living neurons,” said Hersam.

Related Links
Northwestern University 


Gold Member
12-Channel ECG
CM1200B
Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
New
POC Respiratory/Sore Throat Test
BIOFIRE SPOTFIRE (R/ST) Panel
New
Medical Adhesive
MED 5570U
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Health IT

view channel
Photo courtesy of Adobe Stock

Automated System Classifies and Tracks Cardiogenic Shock Across Hospital Settings

Cardiogenic shock remains a difficult, time-sensitive emergency, with delayed identification driving poor outcomes and persistently high mortality. Many cases go undocumented even at advanced stages, hindering... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.